Efikasi Pemantauan Hemodinamik Non-Invasif Pada Pasien Gagal Jantung: Literature Review
DOI:
https://doi.org/10.30651/jkm.v7i3.14104Keywords:
Heart failure, Hemodynamics, Non-Invasive, MonitoringAbstract
Objectives: Therefore, this literature review aimed to identify the efficacy of non-invasive monitoring to evaluate the hemodynamics of patients with HF.
 Methods: This study was a literature review. Keywords include “heart failure patients†AND “non-invasive hemodynamic monitoring†AND “invasive hemodynamic monitoring†and searched extensively through Springer Link, PubMed, and Science Direct. Data analysis was assisted by a data extraction table and qualitative analysis.
 Result: Seven articles were included in the qualitative analysis after being selected through the title, abstract, and inclusion-exclusion criteria. The analysis revealed that non-invasive hemodynamic monitoring in heart failure patients could be carried out in the Intensive Care Unit, non-intensive care unit, and at home. The Non-invasive Pulse Contour Analysis (NPCA), caretaker BP device, and Photoplethysmography-Based Device were used in the ICU. While in the non-ICU, Ballistocardiography (BCG) and Impedance Cardiography (ICG) were used, and Non-Invasive Telemonitoring in bioimpedance monitoring can be used in the home setting.
Â
 Conclusions: Overall, the use of technology to monitor hemodynamics in heart failure patients non-invasively had good validation and efficacy compared with invasive monitoring. Furthermore, this non-invasive technology can be used in the ICU, in Non-ICU settings, and at home (telemonitoring).
References
Annisa Pratiwi, C., Madona, P., & Palapa Wijaya, Y. (2016). Akuisisi Data Sinyal Photoplethysmograph (PPG) Menggunakan Photodioda. Jurnal Elektro Dan Mesin Terapan, 2(2), 32–41. https://doi.org/10.35143/elementer.v2i2.187
Donaho, E. K., & Trupp, R. J. (2009). Hemodynamic Monitoring in Heart Failure: A Nursing Perspective. Heart Failure Clinics, 5(2), 271–278. https://doi.org/10.1016/j.hfc.2008.11.006
Dorsey, E. R., & Topol, E. J. (2016). State of telehealth. New England Journal of Medicine, 375, 154–161.
Dovancescu, S., Torabi, A., Mabote, T., Caffarel, J., Kelkboom, E., Aarts, R., Korsten, E., & Cleland, J. (2013). Sensitivity of a wearable bioimpedance monitor to changes in the thoracic fluid content of heart failure patients. Computing in Cardiology, 40, 927–930.
Dvir, A., Goldstein, N., Rapoport, A., Balmor, R. G., Nachman, D., Merin, R., Fons, M., Ben Ishay, A., & Eisenkraft, A. (2022). Comparing Cardiac Output Measurements Using a Wearable, Wireless, Noninvasive Photoplethysmography-Based Device to Pulse Contour Cardiac Output in the General ICU: A Brief Report. Critical Care Explorations, 4(2), e0624. https://doi.org/10.1097/cce.0000000000000624
Eurlings, C. G. M. J., Boyne, J. J., de Boer, R. A., & Brunner-La Rocca, H. P. (2019). Telemedicine in heart failure—more than nice to have? Netherlands Heart Journal, 27(1), 5–15. https://doi.org/10.1007/s12471-018-1202-5
Faragli, A., Abawi, D., Quinn, C., Cvetkovic, M., Schlabs, T., Tahirovic, E., Düngen, H. D., Pieske, B., Kelle, S., Edelmann, F., & Alogna, A. (2021). The role of non-invasive devices for the telemonitoring of heart failure patients. Heart Failure Reviews, 26(5), 1063–1080. https://doi.org/10.1007/s10741-020-09963-7
Gratz, I., Deal, E., Spitz, F., Baruch, M., Allen, I. E., Seaman, J. E., Pukenas, E., & Jean, S. (2017). Continuous Non-invasive finger cuff CareTaker® comparable to invasive intra-arterial pressure in patients undergoing major intra-abdominal surgery. BMC Anesthesiology, 17(1), 48. https://doi.org/10.1186/s12871-017-0337-z
Hartawan, I. N. B. (2016). Pemantauan Hemodinamik. In PKB Ilmu Kesehatan Anak XVI.
Herman, Istianah, U., & Suryani, E. (2015). Hubungan Pemenuhan Kebutuhan Istirahat Tidur Pada Pasien General Anestesi Di RSUD Nene Mallomo Kabupaten Sidenreng Rappang Sulawesi Selatan. In Caring (Vol. 2, Issue 4, pp. 22–33).
Khraim, F., Alhamaydeh, M., Faramand, Z., Saba, S., & Al-Zaiti, S. (2020). A Novel Non-Invasive Assessment of Cardiac Hemodynamics in Patients With Heart Failure and Atrial Fibrillation. Cardiology Research, 11(6), 370–375. https://doi.org/10.14740/cr1110
Kwon, Y., Stafford, P. L., Enfield, K., Mazimba, S., & Baruch, M. C. (2021). Continuous Noninvasive Blood Pressure Monitoring of Beat-By-Beat Blood Pressure and Heart Rate Using Caretaker Compared With Invasive Arterial Catheter in the Intensive Care Unit. Journal of Cardiothoracic and Vascular Anesthesia, 000, 1–10. https://doi.org/10.1053/j.jvca.2021.09.042
Loodie Ackly Agu & eka, T. (2018). Pemantau Hemodinamik dari Invasif menuju Tidak Invasif Hemodynamic Monitor from invasive to non invasive. 36(6), 128–137.
Lopes, B. S., Craveiro, N., Firmino-Machado, J., Ribeiro, P., & Castelo-Branco, M. (2019). Hemodynamic differences among hypertensive patients with and without heart failure using impedance cardiography Bruno. Therapeutic Advances in Cardiovascular Disease, 13(1–9), 259–261. https://doi.org/10.1177/https
Muti, R. T. (2020). Pengaruh Posisi Semi Fowler Dengan Kombinasi Lateral Kanan Terhadap Perubahan Haemodinamik Pada Pasien Gagal Jantung Di Ruang Iccu Rumah Sakit Umum Daerah Margono Soekarjo Purwokerto. VIiva Medika, 13(2), 50–63.
Nachman, D., Gepner, Y., Goldstein, N., Kabakov, E., Ishay, A. Ben, Littman, R., Azmon, Y., Jaffe, E., & Eisenkraft, A. (2020). Comparing blood pressure measurements between a photoplethysmography-based and a standard cuff-based manometry device. Scientific Reports, 10(1), 1–9. https://doi.org/10.1038/s41598-020-73172-3
Nachman, D., Rahamim, E., Kolben, Y., Mengesha, B., Elbaz-Greener, G., Amir, O., & Asleh, R. (2021). In search of clinical impact: Advanced monitoring technologies in daily heart failure care. Journal of Clinical Medicine, 10(20). https://doi.org/10.3390/jcm10204692
Roth, S., Fox, H., Fuchs, U., Schulz, U., Costard-Jäckle, A., Gummert, J. F., Horstkotte, D., Oldenburg, O., & Bitter, T. (2018). Noninvasive pulse contour analysis for determination of cardiac output in patients with chronic heart failure. Clinical Research in Cardiology, 107(5), 395–404. https://doi.org/10.1007/s00392-017-1198-7
Sengeløv, M., & Biering-Sørensen, T. (2021). Noninvasive Hemodynamic Evaluation at Rest in Heart Failure with Preserved Ejection Fraction. Heart Failure Clinics, 17(3), 423–434. https://doi.org/10.1016/j.hfc.2021.02.006
Setiyawan. (2016). Mean arterial pressure non invasif blood pressure (MAP-NIBP ) pada lateral position dalam perawatan intensif : Studi literature. Prodi S-1 Keperawatan STIKes Kusuma Husada Surakarta, 5, 565–569.
Veenis, J. F., & Brugts, J. J. (2020). Remote monitoring of chronic heart failure patients: invasive versus non-invasive tools for optimising patient management. Netherlands Heart Journal, 28(1), 3–13. https://doi.org/10.1007/s12471-019-01342-8
Wulan, E. S., & Rohmah, W. N. (2019). Gambaran Caring Perawat Dalam Memberikan Asuhan Keperawatan Di Ruang Intensive Care Unit (Icu) Rsud Raa Soewondo Pati. Jurnal Keperawatan Dan Kesehatan Masyarakat Cendekia Utama, 8(2), 120. https://doi.org/10.31596/jcu.v8i2.410
Zhang, L., Cai, P., Deng, Y., Lin, J., Wu, M., Xiao, Z., Chu, Z., Shi, Q., Ye, F., Hu, J., Yang, C., Li, P., Zhuang, S., & Wang, B. (2021). Using a non-invasive multi-sensor device to evaluate left atrial pressure: an estimated filling pressure derived from ballistocardiography. Annals of Translational Medicine, 9(20), 1587–1587. https://doi.org/10.21037/atm-21-5161
Downloads
Published
Issue
Section
License
- Penulis tetap memegang hak atas karyanya dan memberikan hak publikasi pertama kepada jurnal ini yang secara simultan karya tersebut dilisensikan di bawah:Â Creative Commons Attribution-ShareAlike 4.0 International (CC BY-SA 4.0)